Partly cloudy
18 °C
Germantown, Maryland
Partly cloudy

Tue Aug 14 2018
none

Compensated and Calibrated Pressure Sensors: DCXL

By Duff and Macintosh

FEATURES
  • Low pressure measurement from 1 to 30 inch water column
  • (2.5 to 75 mbar)
  • Gage or differential pressure
  • Calibrated and precision temperature compensated
  • Proprietary offset error compensation technique
  • Redesigned housing for optimum stress isolation
  • Matched pressure port volumes

 

GENERAL DESCRIPTION
 
The DCXL series offers OEM customers gage or differential low pressure measurement from 1 to 30 inch water column (2.5 to 75 mbar). A proprietary dual chip compensation technique provides for highest offset stability in respect of temperature changes, warm-up, lifetime and position sensitivity in comparison to conventional sensors. The DCXL sensors feature high accuracy and are calibrated and precision temperature compensated from 0 to 50 °C.
 
The DCXL series of precision low pressure sensors features a redesigned stress concentration enhanced structure for improved performance characteristics. In this new design, the outer package embodying the two mounting holes is mechanically decoupled from the inner part holding the silicon sensing elements to ensure optimum stress isolation. Further, the new sensor package now includes matched pressure port volumes enhancing dynamic response times for fast pressure transient applications.
 
The industry-standard ported package is ideally suited for PCB mount applications with process connections via tubing or manifold mounting. This ease of use makes the DCXL ideal for many medical and HVAC devices as well as industrial instrumentation and environmental control.
 

TECHNICAL SPECIFICATIONS

Pressure ranges Differential / Gage / Vacuum

0...1 to 0...30 inch H2

(0...2.5 to 0...75 mbar)

Output signal (typical)
at Vs = 12 V
0...20 mV
Non-linearity and hysteresis
(typical, combined)
±0.05 %FSS
Pressure connection tube fitting (Ø 4 mm)
Size without nipples and pins (approx.) 28 x 28 x 13 mm