IS YOUR DIESEL GENERATOR COSTING YOU MONEY?

28-08-2015
by 
in 

When the electrical grid fails it doesn't mean that you can too. This is never convenient and can happen when crucial work is underway. When the power blacks out and seasonal productivity just can't wait, you turn to your diesel generator to power the equipment and facilities that are paramount to your success.

Your diesel generator is your backup lifeline during a power outage. Functional standby power means that when electricity fails you can tap into an alternative power source at a moment's notice and avoid being crippled by the situation.

Too often a diesel generator won’t start when it’s needed, resulting in paralysed productivity and lost revenue. Routine inspection and regular preventative maintenance are important to keeping your generator in top condition. These are the five issues that affect generators and the inspection protocols needed to properly address them.

Stick to a weekly general inspection schedule.

Check the batteries for sulphate build-up on the terminals and leads

Once build-up has reached a certain level, a battery can no longer generate enough of a current for an electrical charge and will need to be replaced. Standard procedure on battery replacement is usually every three years. Check with the manufacturer of your generator for their recommendations. Loose or dirty cable connections can also cause a battery to fail or perform poorly. You should tighten and clean the connections to ensure a strong current flow and use terminal grease to avoid sulphate build-up. 

Check the fluids to ensure optimum levels

Oil level and oil pressure are crucial as is the fuel level, the fuel line, and the coolant level. If your generator continually has low levels of any fluid, coolant for example, there is a chance you have an internal leak somewhere in the unit. Some fluid leaks are caused by running the unit at a load that is considerably lower than the output level it is rated for. Diesel generators should be run at a minimum of 70% to 80% – so when they are run at a low load the unit can over-fuel, which causes "wet stacking" and leaks known as "engine slobber."

Check the engine for abnormalities

Run the genset briefly every week and listen for rattles, and whining. If it is knocking about on its mounts, tighten them down.  Look for unusual amounts of exhaust gas and excess fuel usage. Check for oil and water leaks.

Check the exhaust system

Leaks can occur along the exhaust line, usually at the connection points, the welds, and the gaskets. These should be repaired immediately.

Inspect the cooling system 

Check the anti-freeze/water/coolant ratio recommended for your particular generator model according to your climate and the manufacturer specifications. Also, you can improve the air flow by cleaning off the radiator fins with a low-set air compressor.

Inspect the starter battery

In addition to the above battery protocols, it is important to place a load tester on the starter battery to gauge the output levels. A dying battery will consistently put out lower and lower levels, indicating that it is time for a replacement. Also, if you hire a professional to service any problems detected by your routine inspection, check the unit after they are done. Many times the battery charger needs to be disconnected before service, and the person doing the work forgets to hook it back up before they leave. The indicator on the battery charger should read "OK" at all times. 

Inspect the condition of the fuel

Diesel fuel can degrade over time due to contaminants in the fuel system. This will cause your generator to run inefficiently if degraded fuel stagnates in the engine tank. Run the unit for 30 minutes a month with at least one-third the rated load to move old fuel through the system and to keep all moving parts lubricated. Do not allow your diesel generator to run out of fuel or to even run low. Some units have a low fuel shutdown feature, however if yours does not or if this feature fails, the fuel system will draw air into the fuel lines leaving you with a difficult and/or expensive repair job on your hands. The fuel filters should be changed out for every 250 hours of use or once a year depending on how clean your fuel is based on your environment and the overall condition of the unit.

Inspect the lubrication levels

When you run the unit for 30 minutes every month, be sure to check the oil level before you start it. Remember, if you do it when the engine has been running you have to wait for about 10 minutes after you switch the unit off for the oil to drain back down to the sump. There are variances from on generator to the next depending on the manufacturer, but a good policy is to change the oil and the filter every six months, or every 250 hours of use.

Signs of impending trouble

According to the Energex of Southeast Queensland, the main cause of power outages are cyclones, brush fires, lightning, heavy rainstorms, car accidents and falling trees. During the rain season (November through April), you should be especially vigilant about performing regular maintenance on your generator. There are also times where your area can experience planned interruptions for regular network maintenance. When the power goes out and you need to use your generator, be sure to maximise the output by unplugging all appliances that you do not absolutely need at the time. This will reduce unnecessary signal flow or "line loss" to areas that are not crucial for power.

Don't get caught out in the rain, maintain a reliable diesel generator by performing a regular maintenance routine.

By Jamie Press

Jamie Press writes for diesel generator supplier Able Sales based in Perth, WA and Brisbane, QLD.

Related news & editorials

  1. 21.05.2018
    21.05.2018
    by      In
    New from Control Logic, the Puls Dimension CP range of low-voltage power supplies combines high efficiency, premium quality and reliability, and space saving design from 5 to 20A.
    The advanced electronics in the CP range has unity power factor with minimal heat loss and low inrush current. Features... Read More
  2. 21.05.2018
    21.05.2018
    by      In
    A novel remote hose disconnector from hydraulics specialist Enerpac aims to eliminate the release of hydraulic fluid into the sea during the installation of transition pieces at the base of offshore wind towers.
    The environmentally friendly development – which allows full recovery of all connected... Read More
  3. 21.05.2018
    21.05.2018
    by      In
    Available from Treotham Automation, igus tribo-tape films are ideal for any application where smooth, silent, simple and lubrication-free sliding motion is required. The tribo-tape reduces abrasion, enabling easy sliding and reduced wear. The films can also be used as edge protection and product... Read More
  4. 21.05.2018
    21.05.2018
    by      In
    Packaging greatly influences the branding and integrity of food products. The ability to detect leaks in packaging is essential to ensure the freshness, quality and consistency of food products.
    The last thing a consumer wants is to find that food recently bought from the supermarket is rotten and... Read More