New FCI Wet Gas Thermal Flow Meter for Landfill Biogas Measurement

22-12-2020
FCI ST80-RIGHT-LO

Engineers responsible for landfill biogas recovery and green co-gen electrical energy systems will find the rugged ST80 Series Thermal flow Meter from Fluid Components International (FCI) with its Wet Gas MASSte  technology delivers higher installed accuracy with more reliable measurement in this moist, dirty, demanding environment.

The efficacy of this new wet gas thermal sensor technology was recently demonstrated successfully in a Canadian landfill biogas recovery application.  The wet biogas at this site included relatively high levels of entrained moisture levels at 2.5 to 3 percent, which had caused persistent measurement accuracy problems at one its meter installation locations.

This level of entrained moisture in the landfill’s biogas and its condensation created droplets that frequently caused inaccurate or unstable variable gas flow measurements.  When the existing problematic flow meter was replaced with a new FCI ST80 Flow Meter with its exclusive wet gas flow element, the accuracy, stability, and the repeatability of the biogas measurement greatly improved over the site’s six-month test period.

The heavy-duty ST80 Series Flow Meters are designed for applications in industrial and plant process gas flow measurement in pipe diameters from 25 to 2500 mm and in temperatures up to 454°C.   They feature accuracy of ±1% of reading, ±0.5% of full scale and repeatability of ±0.5% of reading.

 Additionally, a flow meter with low flow sensitivity and wide turndowns is required in landfill gas applications because flow rates of biogas can vary widely based on the process’ maturity and fluctuating plant process demands as well as seasonal variations in temperature and humidity. The ST80 can measure flow rates as low as 0.07 NMPS and provide 100:1 turndown, resulting in an optimum solution for biogas applications.

The measurement principle of thermal mass flow meters involves heat transfer caused by gas flow. Any moisture or condensate in the gas stream that intermittently contacts the sensors, however, can cause a sudden, momentary change in the heat transfer rate and result in spiking or fluctuating readings.

The ST80 meter outfitted with FCI’s unique wet gas sensor provides a patent-pending mechanical configuration that shunts entrained moisture in biogas away from the sensor that prevents condensate from reaching the sensors thereby resulting in a stable, repeatable biogas flow meter.  

In addition to moisture and condensation, landfill gas and other biogases are a mixed composition of potentially explosive gases comprised primarily of methane (CH4) and carbon dioxide (CO2), hydrogen sulphide (H2S) and traces of other gases. The instrumentation installed in these applications requires independent agency approvals to protect people, equipment and plants. 

FCI’s ST80 Series has Div.1/Zone 1 level approvals on the complete instrument (electronics, enclosures, and flow sensor elements) for global agencies, including FM, FMc, ATEX, IECEx, and more to ensure their safe application in hazardous installations.

The residuals and particulates in the biogas, along with the H2S component, is a corrosive condensate that deposits itself on the pipe wall and instruments in the pipe. These particulates and residual liquids can clog or foul orifice, vortex shedding, PD, turbine and most other flow meter technology sensors.

In comparison, thermal mass flow meters such as the FCI ST80 have no moving parts or orifices to clog, and their insertion-style design is easily installed in the pipe through a ball valve for simple retraction of the flow element from the pipe for periodic cleaning if needed.

The ST80 flow meter’s outputs and user interface choices are extensive for interface with virtually any control system and/or set-up or configuration devices. Standard outputs include dual, NAMUR NE43 compliant 4-20 mA analogue outputs, HART (version 7), Modbus 485 and a USB port. Foundation Fieldbus or PROFIBUS PA or DP can be optionally added.

The ST80 meter’s optional backlit LCD display provides digital and bar graph readouts of the flow rate and temperature, totalized flow, alarms, diagnostics feedback and even a user defined label/tag field.  Also optional are a four-button keypad for instrument set-up and diagnostics interrogation.

These buttons are activated through the glass so there is never a need to open the ST80 enclosure at the process or to remove it from the process to a safe location.  The ST80 is also supplied with free FCI software for performing all set-up and diagnostics from a PC or laptop.

AMS - https://www.ams-ic.com.au/

RELATED NEWS

  1. EXAIR has added a new feature to its range of Line Vac Air Operated Conveyors, which address the variety of unique problems that manufacturers face.
    The Line Vac Air Operated Conveyors offer an efficient way of converting ordinary pipe, hose or tubes into powerful in-line conveyors, which can be...
  2. TURCK has expanded its HF portfolio with three new IO-Link read/write devices, offering improved performance with password protection and condition monitoring. 
    TURCK’s new RFID read/write devices with IO-Link come in three designs: M18 and M30 threaded barrel options; and a Q40 rectangular design...
  3. The importance of greasing bearings when they are moving is often not understood or is overlooked. There is a possibility that the importance is understood but is not done due to practical constraints such as moving machinery and OH&S regulations.
    Grease introduced into a stationary bearing...